Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.421
Filtrar
Más filtros




Intervalo de año de publicación
1.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38743522

RESUMEN

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Remoción de Dispositivos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Remoción de Dispositivos/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/patología
2.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38710669

RESUMEN

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Asunto(s)
Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Hemodinámica/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Femenino , Masculino , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía , Persona de Mediana Edad , Diseño de Prótesis
3.
J Cardiothorac Surg ; 19(1): 279, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715032

RESUMEN

OBJECTIVE: Reports on long-term outcomes of surgical aortic valve replacement (AVR) for patients aged < 60 years are scarce in Japan. Hence, we aimed to evaluate these outcomes in patients aged < 60 years. METHODS: Between March 2000 and December 2020, 1477 patients underwent aortic valve replacement. In total, 170 patients aged < 60 years who underwent aortic valve replacement were recruited. Patients aged < 18 years were excluded. Patient data collected from the operative records and follow-up assessments were reviewed. RESULTS: The mean age was 49 ± 9 years, and 64.1% of patients were male. One-hundred-and-fifty-two patients (89.4%) underwent aortic valve replacement with a mechanical valve and 18 (10.6%) with a bioprosthetic valve. The mean follow-up period was 8.1 ± 5.5 years. No operative mortality occurred, and in-hospital mortality occurred in one patient (0.6%). Ten late deaths occurred, with seven cardiac-related deaths. The overall survival rate was 95.4 ± 1.7%, 93.9 ± 2.3%, 90.6 ± 3.9%, and 73.2 ± 11.8% at 5, 10, 15, and 20 years, respectively. Freedom from major bleeding was 96.4 ± 1.6% at 5, 10, and 15 years, and 89.0 ± 7.3% at 20 years. Freedom from thromboembolic events was 98.7 ± 1.3%, 97.3 ± 1.9%, 90.5 ± 4.5%, and 79.0 ± 11.3% at 5, 10, 15, and 20 years, respectively. Freedom from valve-related reoperation was 99.4 ± 0.6% at 5 years, 97.8 ± 1.7% at 10 and 15 years, and 63.9 ± 14.5% at 20 years. CONCLUSIONS: Patients aged < 60 years undergoing aortic valve replacement with a high mechanical valve implantation rate had favorable long-term outcomes.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Adulto , Bioprótesis , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Japón/epidemiología , Estudios de Seguimiento , Resultado del Tratamiento , Tasa de Supervivencia/tendencias , Factores de Edad , Factores de Tiempo , Mortalidad Hospitalaria
4.
Inn Med (Heidelb) ; 65(5): 431-438, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38635087

RESUMEN

The pathophysiology of aortic valve diseases is of predominantly degenerative nature, characterized by calcific aortic valve stenosis, which is associated with a reduction in prognosis. The prevalence of aortic valve insufficiency also increases with advancing age. Timely causal treatment is crucial in the management of aortic valve diseases. Following the indication for intervention, the heart team plays a central role in evaluating the results and making therapeutic decisions that consider the patient's preferences. In the assessment of treatment options, considerations regarding the long-term perspective are particularly crucial, especially in younger patients. The most common therapeutic approach for aortic valve diseases is the introduction of a new valve prosthesis. In the majority of cases, this is now achieved through catheter-based implantation of a bioprosthetic heart valve, known as transcatheter aortic valve implantation (TAVI). Open surgical aortic valve replacement (AVR) is favored in younger patients with low surgical risk or in the case that TAVI is not feasible. In AVR, both biological and the longest-lasting mechanical prosthesis types are used. Surgical repair techniques are primarily applied in cases of aortic valve regurgitation. Notably, TAVI, as well as surgical procedures for the treatment of aortic valve diseases, have undergone significant advancements in recent years, including expanded indications for TAVI and, on the surgical side, in particular the development of minimally invasive surgical techniques.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Prótesis Valvulares Cardíacas , Enfermedad de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Bioprótesis
5.
Int J Mol Sci ; 25(7)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38612836

RESUMEN

One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient's immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve's ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Animales , Porcinos , Humanos , Niño , Xenoinjertos , Trasplante Heterólogo , Ingeniería de Tejidos
6.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584521

RESUMEN

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Enfermedad Iatrogénica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ablación por Catéter/efectos adversos , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Agujas , Función Ventricular Izquierda , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Oclusión Coronaria/fisiopatología , Angiografía Coronaria
7.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627820

RESUMEN

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombocitopenia , Humanos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Trombocitopenia/etiología , Factores de Riesgo , Progresión de la Enfermedad
8.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589959

RESUMEN

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Asunto(s)
Bioprótesis , Endocarditis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Micosis , Humanos , Masculino , Adulto Joven , Aorta/cirugía , Aorta Torácica/cirugía , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Endocarditis/diagnóstico , Endocarditis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/efectos adversos
9.
BMJ Case Rep ; 17(4)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684360

RESUMEN

A patient in his 60s with a bioprosthetic aortic and mitral valve replacement presented with dyspnoea, tiredness and dizziness 2 years postoperatively. Transthoracic echocardiography showed mitral valve stenosis and increased pulmonary artery pressure suggesting bioprosthetic valve failure. Cardiac CT confirmed the diagnosis of bioprosthetic mitral valve thrombosis. Treatment with anticoagulation resulted in a remarkable improvement of the valve area and gradient and complete resolution of the thrombus. Herein, we report a case of rare bioprosthetic mitral valve thrombosis.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Válvula Mitral , Trombosis , Tomografía Computarizada por Rayos X , Humanos , Masculino , Bioprótesis/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/tratamiento farmacológico , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Anticoagulantes/uso terapéutico , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Persona de Mediana Edad , Falla de Prótesis
10.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38578295

RESUMEN

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Asunto(s)
Bioprótesis , Endocarditis Bacteriana , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Tricúspide , Masculino , Humanos , Persona de Mediana Edad , Adulto , Bioprótesis/efectos adversos , Constricción Patológica , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Estenosis de la Válvula Tricúspide/diagnóstico por imagen , Estenosis de la Válvula Tricúspide/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Falla de Prótesis
11.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594705

RESUMEN

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Válvula Aórtica/cirugía , Resultado del Tratamiento
12.
J Cardiothorac Surg ; 19(1): 174, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38576006

RESUMEN

BACKGROUND: There is ambiguity in the literature regarding the continuous suture technique (CST) for aortic valve replacement (AVR). At our center, there has been a gradual shift towards CST over the interrupted pledgeted technique (IPT). This study aims at comparing outcomes for both techniques. METHODS: We performed a retrospective analysis of a single-center study of patients undergoing AVR between January 2011 and July 2020. Patients were divided into two groups: Continuous suture technique and interrupted pledget-reinforced sutures. The pre-operative and In-hospital clinical characteristics and echocardiographic hemodynamics (i.e. transvalvular gradients and paravalvular leakage) were compared between CST and IPT. RESULTS: We compared 791 patients with CST to 568 patients with IPT (median age: 73 and 74 years, respectively, p = 0.02). In CST there were 35% concomitant procedure vs. 31% in IPT (p = 0.16). Early mortality was 3.2% in CST versus 4.8% in IPT (p = 0.15), and a second cross-clamp due to a paravalvular-leak in 0.5% vs. 1.2%, respectively (p = 0.22). The CST was not associated with new-onset conduction-blocks mandating pacemaker implants(OR 1.07, 95% CI 0.54-2.14; P = 0.85). The postoperative gradients on echocardiography were lower in CST compared to IPT, especially in smaller annuli (peak gradients: 15.7mmHg vs. 20.5mmHg, in valve size < 23 mm, p < 0.001). CONCLUSIONS: The continuous suture technique was associated with lower postoperative gradients and shorter cross-clamp time compared to interrupted pledgeted technique. Differences in paravalvular leaks were non-significant, although slightly less in the continuous suture technique. There were no further differences in valve-related complications. Hence, continues suture technique is safe, with better hemodynamics compared to the interrupted pledgeted technique. This may be of clinical importance, especially in smaller size annular size.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Técnicas de Sutura , Resultado del Tratamiento , Diseño de Prótesis
13.
J Mater Sci Mater Med ; 35(1): 26, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38683259

RESUMEN

OBJECTIVE: Aortic valve neocuspidization (AVNeo) using autologous pericardium is a promising technique. Expected advantages are reduced immune response, appropriate biomechanics and lower treatment expenses. Nevertheless, autologous pericardium can be affected by patient's age and comorbidities. Usually, glutaraldehyde (GA) - fixed bovine pericardium is the basic material for aortic valve prostheses, easy available and carefully pre-examined in a standardized fabrication process. Aim of the study is the verification of autologous pericardial tissue homogeneity by analysing tissue thickness, biomechanics and extracellular matrix (ECM) composition. METHODS: Segments of human GA-fixed pericardium selected by the surgeon based on visual criteria for cusp pre-cut and remaining after surgical AV replacement were investigated in comparison to bovine standard tissue treated equivalently. Pericardium sampling was performed at up to three positions of each sutured cusp for histological or biomechanical analysis, according to tissue availability. RESULTS AND CONCLUSIONS: Human pericardia exhibited a higher heterogeneity in collagen content, density of vessel structures and elastic moduli. Thickness, vessel density and collagen and elastin content differed significantly between the species. In contrast, significant interindividual differences were detected in most properties investigated for human pericardial samples but only for tissue thickness in bovine tissues. Higher heterogeneity of human pericardium, differing vessel and collagen content compared to bovine state-of-the-art material might be detrimental for long term AV functionality or deterioration and have to be intensely investigated in patients follow up after autologous cusp replacement.


Asunto(s)
Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Pericardio , Bovinos , Humanos , Válvula Aórtica/cirugía , Animales , Fenómenos Biomecánicos , Masculino , Femenino , Anciano , Matriz Extracelular/química , Persona de Mediana Edad , Colágeno/química , Glutaral/química , Ensayo de Materiales , Implantación de Prótesis de Válvulas Cardíacas/métodos
15.
JACC Cardiovasc Interv ; 17(6): 727-737, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38456879

RESUMEN

BACKGROUND: Coronary re-engagement after transcatheter aortic valve replacement (TAVR) using self-expanding transcatheter heart valves (THVs) systematically implanted using commissural alignment (CA) techniques has been poorly investigated. OBJECTIVES: The aim of this study was to evaluate unsuccessful coronary cannulation, and its predictors, after TAVR using self-expanding devices implanted using CA techniques. METHODS: RE-ACCESS 2 (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent 2) was an investigator-driven, single-center, prospective study that enrolled consecutive TAVR patients receiving Evolut and ACURATE THVs implanted using CA techniques. The primary endpoint was unsuccessful coronary cannulation after TAVR. The secondary endpoint was the identification of postprocedural predictors of unfeasible, selective coronary ostia re-engagement on computed tomographic angiography performed after TAVR. RESULTS: Among 127 patients enrolled from September 2021 to December 2022, 7 (5.5%) had unsuccessful coronary cannulation after TAVR, and 6 of them received Evolut THVs (7.5% vs 2.3%; P = 0.26). Failure of left coronary artery cannulation was similar between Evolut and ACURATE THVs (2.5% vs 2.1%; P = 1.00), whereas that of right coronary artery cannulation was prevalent in the Evolut group (6.3% vs 0.0%; P = 0.16). Coronary overlap was associated with the inability to selectively cannulate the right coronary artery (OR: 5.6; 95% CI: 1.2-25.8; P = 0.03), but not in ACURATE recipients (P = 0.39). Severe misalignment of Evolut THVs was associated with the inability to selectively cannulate both coronary arteries (OR: 24.7; 95% CI: 1.9-312.9; P = 0.01). CONCLUSIONS: Unsuccessful coronary cannulation after TAVR using self-expanding THVs implanted using CA techniques was reported in 5.5% of cases, with the majority involving the Evolut THV. Commissural misalignment affected coronary cannulation after TAVR mostly in Evolut recipients.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Factores de Riesgo , Diseño de Prótesis , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Cateterismo
16.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506737

RESUMEN

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Int J Biol Macromol ; 266(Pt 2): 130715, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38462108

RESUMEN

With an aging population, the patients with valvular heart disease (VHD) are growing worldwide, and valve replacement is a primary choice for these patients with severe valvular disease. Among them, bioprosthetic heart valves (BHVs), especially BHVs trough transcatheter aortic valve replacement, are widely accepted by patients on account of their good hemodynamics and biocompatibility. Commercial BHVs in clinic are prepared by glutaraldehyde cross-linked pericardial tissue with the risk of calcification and thrombotic complications. In the present study, a strategy combines improved hemocompatibility and anti-calcification properties for BHVs has been developed based on a novel non-glutaraldehyde BHV crosslinker hexakis(hydroxymethyl)melamine (HMM) and the anticoagulant fucoidan. Besides the similar mechanical properties and enhanced component stability compared to glutaraldehyde crosslinked PP (G-PP), the fucoidan modified HMM-crosslinked PPs (HMM-Fu-PPs) also exhibit significantly enhanced anticoagulation performance with a 72 % decrease in thrombus weight compared with G-PP in ex-vivo shunt assay, along with the superior biocompatibility, satisfactory anti-calcification properties confirmed by subcutaneous implantation. Owing to good comprehensive performance of these HMM-Fu-PPs, this simple and feasible strategy may offer a great potential for BHV fabrication in the future, and open a new avenue to explore more N-hydroxymethyl compound based crosslinker with excellent performance in the field of biomaterials.


Asunto(s)
Anticoagulantes , Bioprótesis , Prótesis Valvulares Cardíacas , Polisacáridos , Polisacáridos/química , Polisacáridos/farmacología , Anticoagulantes/química , Anticoagulantes/farmacología , Animales , Coagulación Sanguínea/efectos de los fármacos , Humanos , Conejos , Ensayo de Materiales , Trombosis/prevención & control , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Reactivos de Enlaces Cruzados/química , Calcificación Fisiológica/efectos de los fármacos
18.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-38465492

RESUMEN

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Femenino , Humanos , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Tórax , Prótesis Valvulares Cardíacas/efectos adversos , Dolor en el Pecho/etiología , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
19.
Curr Probl Cardiol ; 49(6): 102534, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38521294

RESUMEN

The following letter presents an answer of a comment of our work titled "Ross procedure: valve function, clinical outcomes and predictors after 25 years' follow-up," recently published in your journal by Rangwala et al.1 As our colleagues point out, the Ross procedure has excellent survival rates but a significant risk of valve dysfunction and therefore reintervention at follow-up. Although the survival advantage with the Ross procedure appears to be consistent compared with mechanical valve substitutes, this benefit is not as clear compared with biological valve substitutes. However, biological valve substitutes also have significant reintervention rates during follow-up. The different surgical modifications of the Ross procedure have not clearly demonstrated better results in follow-up in terms of autograft reintervention. This procedure can be performed in a medium-volume center with good results as long as adequate patient selection and adequate surgical training are carried out.


Asunto(s)
Válvula Aórtica , Humanos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/cirugía , Válvula Pulmonar/trasplante , Prótesis Valvulares Cardíacas , Estudios de Seguimiento , Bioprótesis , Procedimientos Quirúrgicos Cardíacos/métodos , Reoperación/estadística & datos numéricos , Enfermedades de las Válvulas Cardíacas/cirugía
20.
Innovations (Phila) ; 19(2): 125-135, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38465600

RESUMEN

OBJECTIVE: The surgical treatment of aortic stenosis continues to evolve, and sutureless aortic valve replacement (SUAVR) is an emerging technology. With the Perceval S (Corcym, London, UK) as the only true sutureless valve on the market, the objective of this review is to analyze the current literature on Perceval S. Focusing on valve design and deployment as well as applications of the technology for challenging pathology, clinical outcomes are assessed, including a comparison with transcatheter AVR (TAVR). METHODS: PubMed and MEDLINE were searched by 3 authors for studies analyzing SUAVR from inception to May 19, 2023. RESULTS: SUAVR facilitates minimally invasive surgery and offers an alternative strategy for patients with small aortic annuli. It also has a time-saving advantage for patients who require complex operations. SUAVR results in excellent long-term morbidity, mortality, durability, and hemodynamic function. In comparison with conventional surgical AVR (SAVR), SUAVR does have a greater risk of postoperative pacemaker implantation; however, increasing user experience and refinements in implantation technique have contributed to reductions in this outcome. SUAVR results in morbidity and mortality that is similar to rapid-deployment AVR. Midterm outcomes are superior to TAVR; however, further robust investigation into all of these comparisons is ultimately necessary. CONCLUSIONS: SUAVR bridges the gap in technology between SAVR and TAVR. The application of this exciting technology will undoubtedly grow in the coming years, during which additional investigation is paramount to optimize preoperative planning, valve deployment, and reintervention strategies.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Diseño de Prótesis , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA